Revised guidance for long-serving drives
On 6 November 2026, Cisco revised Field Notice FN74426 to version 2.0. The original notice was issued on 21 September. The revision expands remediation guidance for additional affected SSD families.
Certain SATA SSDs deployed in UCS and HyperFlex environments can experience substantial performance degradation after 65,535 power-on hours. Cisco recommends the applicable corrective firmware. Temporary recovery after a power cycle is not a lasting resolution.
Why operating hours alone do not justify replacement
Data centres often operate functional drives across multiple hardware generations. A healthy SMART status alone cannot rule out every firmware-related performance issue. In shared storage environments, increased latency can affect applications even when their own servers appear healthy.
Neither blanket replacement nor ignoring the notice is appropriate. Teams need to identify the exact product identifier, installed firmware and accumulated operating hours. Before intervention, establish the system's redundancy and the condition of neighbouring drives.
Plan maintenance with controlled risk
Nivando recommends a targeted inventory of existing systems. Map drives to their servers and clusters, compare product identifiers and firmware against the manufacturer's guidance, and prioritise business-critical services. Define measurable acceptance criteria for I/O performance.
Coordinate changes with storage owners, service management and field engineering. Verify recovery capability, compatibility and available maintenance windows. After intervention, confirm both the firmware version and actual system performance. Documenting outcomes makes subsequent maintenance at other sites more predictable.